Zoho ManageEngine OpManager Stable build before 125203 (and Released build before 125233) allows Remote Code Execution via the Smart Update Manager (SUM) servlet.
An issue was discovered in Foxit Reader and PhantomPDF before 10.1. If TslAlloc attempts to allocate thread local storage but obtains an unacceptable index value, V8 throws an exception that leads to a write access violation (and read access violation).
In setInstallerPackageName of PackageManagerService.java, there is a missing permission check. This could lead to local escalation of privilege and granting spurious permissions with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-8.0 Android-8.1 Android-9 Android-10 Android-11Android ID: A-150857253
In Moodle before 3.9.1, 3.8.4, 3.7.7 and 3.5.13, yui_combo needed to limit the amount of files it can load to help mitigate the risk of denial of service.
An issue was discovered in BigBlueButton through 2.2.29. When at attacker is able to view an account_activations/edit?token= URI, the attacker can create an approved user account associated with an email address that has an arbitrary domain name.
In FreeBSD 12.1-STABLE before r359565, 12.1-RELEASE before p7, 11.4-STABLE before r362975, 11.4-RELEASE before p1, and 11.3-RELEASE before p11, missing synchronization in the IPV6_2292PKTOPTIONS socket option set handler contained a race condition allowing a malicious application to modify memory after being freed, possibly resulting in code execution.
The ECDSA operation of the micro-ecc library 1.0 is vulnerable to simple power analysis attacks which allows an adversary to extract the private ECC key.
An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpy_s() if a local user opens FactoryTalk Diagnostics Viewer (FTDiagViewer.exe) to view the log entry. Observed in FactoryTalk Diagnostics 6.11. All versions of FactoryTalk Diagnostics are affected.
In Libav 12.3, there is a heap-based buffer over-read in vc1_decode_b_mb_intfi in vc1_block.c that allows an attacker to cause denial-of-service via a crafted file.
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service.
GNU LibreDWG 0.9.3.2564 has a heap-based buffer over-read in bit_search_sentinel in bits.c.
An issue was discovered on Samsung mobile devices with P(9.0) software. Gallery leaks cached data. The Samsung IDs are SVE-2019-16010, SVE-2019-16011, SVE-2019-16012 (January 2020).
An issue was discovered on Samsung mobile devices with O(8.x) (with TEEGRIS) software. The Gatekeeper Trustlet allows a brute-force attack on user credentials. The Samsung ID is SVE-2020-16908 (June 2020).
libde265 v1.0.4 contains a heap buffer overflow in the put_weighted_bipred_16_fallback function, which can be exploited via a crafted a file.
An issue was discovered in HCC Nichestack 3.0. The code that generates Initial Sequence Numbers (ISNs) for TCP connections derives the ISN from an insufficiently random source. As a result, an attacker may be able to determine the ISN of current and future TCP connections and either hijack existing ones or spoof future ones. (Proper ISN generation should aim to follow at least the specifications outlined in RFC 6528.)
A directory traversal vulnerability in file upload function of Gotenberg through 6.2.1 allows an attacker to upload and overwrite any writable files outside the intended folder. This can lead to DoS, a change to program behavior, or code execution.
The Treck TCP/IP stack before 6.0.1.66 has an Ethernet Link Layer Integer Underflow.
QED ResourceXpress Qubi3 devices before 1.40.9 could allow a local attacker (with physical access to the device) to obtain sensitive information via the debug interface (keystrokes over a USB cable), aka wireless password visibility.
In JetBrains YouTrack versions before 2020.3.4313, 2020.2.11008, 2020.1.11011, 2019.1.65514, 2019.2.65515, and 2019.3.65516, an attacker can retrieve an issue description without appropriate access.
Certain TP-Link devices have a Hardcoded Encryption Key. This affects NC200 2.1.9 build 200225, N210 1.0.9 build 200304, NC220 1.3.0 build 200304, NC230 1.3.0 build 200304, NC250 1.3.0 build 200304, NC260 1.5.2 build 200304, and NC450 1.5.3 build 200304.