ChinaMobile PLC Wireless Router GPN2.4P21-C-CN devices with firmware W2001EN-00 have an Incorrect Access Control vulnerability via the cgi-bin/webproc?getpage=html/index.html subpage=wlsecurity URI, allowing an Attacker to change the Wireless Security Password.
Linear eMerge E3-Series devices allow Remote Code Execution (root access over SSH).
eQ-3 Homematic AddOn 'CloudMatic' on CCU2 and CCU3 allows uncontrolled admin access, resulting in the ability to obtain VPN profile details, shutting down the VPN service and to delete the VPN service configuration. This is related to improper access control for all /addons/mh/ pages.
Weak file permissions applied to the Aviatrix VPN Client through 2.2.10 installation directory on Windows and Linux allow a local attacker to execute arbitrary code by gaining elevated privileges through file modifications.
Insufficient sanitization of environment variables passed to rsync can bypass the restrictions imposed by rssh, a restricted shell that should restrict users to perform only rsync operations, resulting in the execution of arbitrary shell commands.
Citrix SD-WAN 10.2.x before 10.2.3 and NetScaler SD-WAN 10.0.x before 10.0.8 have Improper Input Validation (issue 6 of 6).
An issue was discovered on Samsung mobile devices with N(7.1), O(8.x), and P(9.0) (released in China) software. The Firewall application mishandles the PermissionWhiteLists protection mechanism. The Samsung ID is SVE-2019-14299 (November 2019).
TP-Link TL-WR840N v5 00000005 devices allow XSS via the network name. The attacker must log into the router by breaking the password and going to the admin login page by THC-HYDRA to get the network name. With an XSS payload, the network name changed automatically and the internet connection was disconnected. All the users become disconnected from the internet.
ChinaMobile GPN2.4P21-C-CN W2001EN-00 is affected by: Incorrect Access Control - Unauthenticated Remote Reboot. The impact is: PLC Wireless Router's are vulnerable to an unauthenticated remote reboot due. The component is: Reboot settings are available to unauthenticated users instead of only authenticaed users. The attack vector is: Remote.
The Alcatel Lucent I-240W-Q GPON ONT using firmware version 3FE54567BOZJ19 allows a remote, unauthenticated attacker to enable telnetd on the router via a crafted HTTP request.
An issue was discovered on AudioCodes Mediant 500L-MSBR, 500-MBSR, M800B-MSBR and 800C-MSBR devices with firmware versions F7.20A at least to 7.20A.252.062. The (1) management SSH and (2) management TELNET features allow remote attackers to cause a denial of service (connection slot exhaustion) via 5 unauthenticated connection attempts, because the maximum number of unauthenticated clients that can be configured is 5. NOTE: the vendor's position is that this is a "design choice.
In Ubiquiti Networks EdgeSwitch X v1.1.0 and prior, a privileged user can execute arbitrary shell commands over the SSH CLI interface. This allows to execute shell commands under the root user.
An Improper Neutralization of Input vulnerability in the Anomaly Detection Parameter Name in Fortinet FortiWeb 6.0.5, 6.2.0, and 6.1.1 may allow a remote unauthenticated attacker to perform a Cross Site Scripting attack (XSS).
Use of Hard-coded Credentials vulnerability in FortiRecorder all versions below 2.7.4 may allow an unauthenticated attacker with knowledge of the aforementioned credentials and network access to FortiCameras to take control of those, provided they are managed by a FortiRecorder device.
A system command injection vulnerability in the FortiAP-S/W2 6.2.1, 6.2.0, 6.0.5 and below, FortiAP 6.0.5 and below and FortiAP-U below 6.0.0 under CLI admin console may allow unauthorized administrators to run arbitrary system level commands via specially crafted ifconfig commands.
An authentication flaw in the AVPNC_RP service in Aviatrix VPN Client through 2.2.10 allows an attacker to gain elevated privileges through arbitrary code execution on Windows, Linux, and macOS.
A stack buffer overflow vulnerability in FortiClient for Linux 6.2.1 and below may allow a user with low privilege to cause FortiClient processes running under root priviledge crashes via sending specially crafted "StartAvCustomScan" type IPC client requests to the fctsched process due the argv data not been well sanitized.
An issue was discovered on Linksys WRT1900ACS 1.0.3.187766 devices. An ability exists for an unauthenticated user to browse a confidential ui/1.0.99.187766/dynamic/js/setup.js.localized file on the router's webserver, allowing for an attacker to identify possible passwords that the system uses to set the default guest network password. An attacker can use this list of 30 words along with a random 2 digit number to brute force their access onto a router's guest network.
A stack-based buffer overflow in the processPrivilage() function in IOS/process-general.c in nipper-ng 0.11.10 allows remote attackers (serving firewall configuration files) to achieve Remote Code Execution or Denial Of Service via a crafted file.
The EnGenius EWS660AP router with firmware 2.0.284 allows an attacker to execute arbitrary commands using the built-in ping and traceroute utilities by using different payloads and injecting multiple parameters. This vulnerability is fixed in a later firmware version.