38275 vulnerabilidades · Web Orden: CVSS EPSS Año ID
CVE-2017-16346
Insteon Web
8.5
HIGH
EPSS
0.8%
2017 1 PoC

An attacker could send an authenticated HTTP request to trigger this vulnerability in Insteon Hub running firmware version 1012. At 0x9d01c368 the value for the s_mac key is copied using strcpy to the buffer at 0xa000170c. This buffer is 25 bytes large, sending anything longer will cause a buffer overflow. The destination can also be shifted by using an sn_speaker parameter between "0" and "3".

CVE-2017-16300
Hub Web
8.5
HIGH
EPSS
0.5%
2017 CWE-121 1 PoC

Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd sn_ex, at 0x9d01ac74, the value for the `id` key is copied using `strcpy` to the buffer at `$sp+0x290`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow.

CVE-2023-35157
xwiki-platform Web
8.5
HIGH
EPSS
1.4%
2023 CWE-80 1 PoC

XWiki Platform is a generic wiki platform offering runtime services for applications built on top of it. It's possible to perform an XSS by forging a request to a delete attachment action with a specific attachment name. Now this XSS can be exploited only if the attacker knows the CSRF token of the user, or if the user ignores the warning about the missing CSRF token. The vulnerability has been patched in XWiki 15.1-rc-1 and XWiki 14.10.6.

CVE-2017-16271
Hub Web
8.5
HIGH
EPSS
0.4%
2017 CWE-121 1 PoC

Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd e_l, at 0x9d016c94, the value for the `as_c` key is copied using `strcpy` to the buffer at `$sp+0x2b0`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow.

CVE-2025-34201
Print Virtual Appliance Host DevOps Web Networking Database
8.5
HIGH
EPSS
0.1%
2025 CWE-653 1 PoC

Vasion Print (formerly PrinterLogic) Virtual Appliance Host and Application (VA and SaaS deployments) run many Docker containers on shared internal networks without firewalling or segmentation between instances. A compromise of any single container allows direct access to internal services (HTTP, Redis, MySQL, etc.) on the overlay network. From a compromised container, an attacker can reach and exploit other services, enabling lateral movement, data theft, and system-wide compromise.

CVE-2017-16319
Hub Web
8.5
HIGH
EPSS
0.4%
2017 CWE-121 1 PoC

Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_sonos, at 0x9d01d7a8, the value for the `g_sonos_index` key is copied using `strcpy` to the buffer at `$sp+0x1b4`.This buffer is 8 bytes large, sending anything longer will cause a buffer overflow.

CVE-2017-16345
Insteon Web
8.5
HIGH
EPSS
0.8%
2017 1 PoC

An attacker could send an authenticated HTTP request to trigger this vulnerability in Insteon Hub running firmware version 1012. At 0x9d01c318 the value for the s_port key is copied using strcpy to the buffer at 0xa00017f4. This buffer is 6 bytes large, sending anything longer will cause a buffer overflow. The destination can also be shifted by using an sn_speaker parameter between "0" and "3".

CVE-2017-16256
Hub Web
8.5
HIGH
EPSS
0.5%
2017 CWE-121 1 PoC

Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd sn_sx, at 0x9d014ebc, the value for the `cmd2` key is copied using `strcpy` to the buffer at `$sp+0x2d0`.This buffer is 100 bytes large, sending anything longer will cause a buffer overflow.

CVE-2017-16258
Hub Web
8.5
HIGH
EPSS
0.5%
2017 CWE-121 1 PoC

Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd sn_sx, at 0x9d014f7c, the value for the `cmd4` key is copied using `strcpy` to the buffer at `$sp+0x2b0`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow.

CVE-2021-39152
xstream Web ⚡ nuclei
8.5
HIGH
EPSS
61.8%
2021 CWE-502 4 PoCs

XStream is a simple library to serialize objects to XML and back again. In affected versions this vulnerability may allow a remote attacker to request data from internal resources that are not publicly available only by manipulating the processed input stream with a Java runtime version 14 to 8. No user is affected, who followed the recommendation to setup XStream's security framework with a whitelist limited to the minimal required types. If you rely on XStream's default blacklist of the [Security Framework](https://x-stream.github.io/security.html#framework), you will have to use at least ve

CVE-2017-16347
Insteon Web
8.5
HIGH
EPSS
0.8%
2017 1 PoC

An attacker could send an authenticated HTTP request to trigger this vulnerability in Insteon Hub running firmware version 1012. At 0x9d01e7d4 the value for the s_vol key is copied using strcpy to the buffer at 0xa0001700. This buffer is maximum 12 bytes large (this is the maximum size it could be, it is possible other global variables are stored between this variable and the next one that we could identify), sending anything longer will cause a buffer overflow.

CVE-2017-16279
Hub Web
8.5
HIGH
EPSS
0.4%
2017 CWE-121 1 PoC

Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_net, at 0x9d0181a4, the value for the `port` key is copied using `strcpy` to the buffer at `$sp+0x280`.This buffer is 16 bytes large, sending anything longer will cause a buffer overflow.

CVE-2017-16313
Hub Web
8.5
HIGH
EPSS
0.4%
2017 CWE-121 1 PoC

Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_sonos, at 0x9d01c084, the value for the `s_ddelay` key is copied using `strcpy` to the buffer at `$sp+0x2b0`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow.

CVE-2017-16285
Hub Web
8.5
HIGH
EPSS
0.4%
2017 CWE-121 1 PoC

Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_time, at 0x9d018e58, the value for the `offset` key is copied using `strcpy` to the buffer at `$sp+0x2d0`.This buffer is 100 bytes large, sending anything longer will cause a buffer overflow.

CVE-2017-16309
Hub Web
8.5
HIGH
EPSS
0.4%
2017 CWE-121 1 PoC

Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd sn_exw, at 0x9d01b3d8, the value for the `d` key is copied using `strcpy` to the buffer at `$sp+0x334`.This buffer is 100 bytes large, sending anything longer will cause a buffer overflow.

CVE-2017-16267
Hub Web
8.5
HIGH
EPSS
0.5%
2017 CWE-121 1 PoC

Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_b, at 0x9d016578, the value for the `val` key is copied using `strcpy` to the buffer at `$sp+0x2b0`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow.

CVE-2017-16292
Hub Web
8.5
HIGH
EPSS
0.4%
2017 CWE-121 1 PoC

Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd g_schd, at 0x9d019c50, the value for the `grp` key is copied using `strcpy` to the buffer at `$sp+0x1b4`.This buffer is 8 bytes large, sending anything longer will cause a buffer overflow.

CVE-2017-16270
Hub Web
8.5
HIGH
EPSS
0.5%
2017 CWE-121 1 PoC

Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_b, at 0x9d01679c, the value for the `s_sonos_cmd` key is copied using `strcpy` to the buffer at `$sp+0x290`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow.

CVE-2017-16290
Hub Web
8.5
HIGH
EPSS
0.4%
2017 CWE-121 1 PoC

Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_sun, at 0x9d01980c, the value for the `sunrise` key is copied using `strcpy` to the buffer at `$sp+0x2d0`.This buffer is 100 bytes large, sending anything longer will cause a buffer overflow.

CVE-2017-16283
Hub Web
8.5
HIGH
EPSS
0.4%
2017 CWE-121 1 PoC

Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_name, at 0x9d0188a8, the value for the `name` key is copied using `strcpy` to the buffer at `$sp+0x2b0`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow.